ZHCSKL7 December 2019 – December 2019 TCAN1044V
PRODUCTION DATA.
| VALUE | UNIT | ||||
|---|---|---|---|---|---|
| VESD | System Level Electro-Static Discharge (ESD)(3) | CAN bus terminals (CANH, CANL) to GND | SAE J2962-2 per ISO 10650
Powered Contact Discharge |
±8000 | V |
| SAE J2962-2 per ISO 10650 Powered Air Discharge | ±15000 | V | |||
| VTran | ISO 7637 ISO Pulse Transients(1) | CAN bus terminals (CANH, CANL) | Pulse 1 | –100 | V |
| Pulse 2a | 75 | V | |||
| Pulse 3a | –150 | V | |||
| Pulse 3b | 100 | V | |||
| ISO 7637 Slow transients pulse(2) | CAN bus terminals (CANH, CANL) to GND | DCC slow transient pulse | ±85 | V | |