ZHCSKL7 December 2019 – December 2019 TCAN1044V
PRODUCTION DATA.
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | ||
|---|---|---|---|---|---|---|---|
| ICC | Supply current normal mode
|
Dominant | See Figure 5,TXD = 0 V, STB = 0 V, RL = 60 Ω, CL = open | 45 | 70 | mA | |
| See Figure 5, TXD = 0 V, STB = 0 V, RL = 50 Ω, CL = open | 49 | 80 | mA | ||||
| Recessive | See Figure 5, TXD = VCC, STB = 0 V, RL = 50 Ω, CL = open, RCM = open | 4.5 | 7.5 | mA | |||
| Dominant with bus fault | See Figure 5, TXD = 0 V, STB = 0 V, CANH = CANL = ±25 V, RL = open, CL = open | 130 | mA | ||||
| ICC | Supply current standby mode
|
TXD = STB = VIO
RL = 50 Ω, CL = open See Figure 5 |
0.2 | 1 | µA | ||
| IIO | IO supply current normal mode | Dominant | TXD = 0 V, STB= 0 V
RXD floating |
125 | 300 | µA | |
| IIO | IO supply current normal mode | Recessive | TXD = 0 V, STB = 0 V
RXD floating |
25 | 48 | µA | |
| IIO | IO supply current standby mode | TXD = 0 V, STB = VIO
RXD floating |
8.5 | 13.5 | µA | ||
| UVVCC | Rising under voltage detection on VCC for protected mode | 4.2 | 4.4 | V | |||
| UVVCC | Falling under voltage detection on VCC for protected mode | 3.5 | 4 | 4.25 | V | ||
| UVVIO | Rising under voltage detection on VIO | 1.56 | 1.65 | V | |||
| UVVIO | Falling under voltage detection on VIO | 1.4 | 1.51 | 1.59 | V | ||