TIDT292 June 2022
The following tables show all values of power factor (PF) and input current harmonic distortion (iTHD) versus output power.
| PF (%) | iTHD (%) | POUT (W) |
|---|---|---|
|
0.00 |
0.00 |
0.00 |
|
10.8 |
10.2 |
3.12 |
|
24.0 |
28.1 |
9.13 |
|
40.4 |
46.7 |
21.25 |
|
61.2 |
37.07 |
51.50 |
|
80.4 |
25.90 |
105.91 |
|
92.5 |
14.52 |
196.49 |
|
98.6 |
6.38 |
401.28 |
| PF (%) | iTHD (%) | POUT (W) |
|---|---|---|
|
0.00 |
0.00 |
0.00 |
|
14.7 |
17.8 |
3.12 |
|
31.9 |
38.2 |
9.12 |
|
50.9 |
42.3 |
21.23 |
|
72.4 |
30.40 |
51.49 |
|
88.9 |
20.17 |
105.86 |
|
96.5 |
9.84 |
196.47 |
|
99.6 |
5.56 |
401.07 |
| PF (%) | iTHD (%) | POUT (W) |
|---|---|---|
|
0.00 |
0.00 |
0.00 |
|
8.0 |
0.0 |
3.13 |
|
18.9 |
19.7 |
9.14 |
|
33.1 |
34.4 |
21.24 |
|
53.1 |
42.06 |
51.49 |
|
70.8 |
30.97 |
105.87 |
|
87.1 |
19.88 |
196.44 |
|
96.7 |
8.05 |
401.23 |