SLVK162A December 2023 – August 2024 TPS7H6003-SP , TPS7H6013-SP , TPS7H6023-SP
Devices were irradiated at three fluence levels in unbiased conditions: 1 × 1012 n / cm2, 5 × 1012 n / cm2 and 1 × 1013 n / cm2.
| Group | Sample Quantity | Neutron Fluence (n / cm2) | Bias |
|---|---|---|---|
| A | 3 | 1.0 × 1012 | Unbiased |
| B | 3 | 5.0 × 1012 | Unbiased |
| C | 3 | 1.0 × 1013 | Unbiased |
| Control Unit | 1 | N/A | N/A |