ZHCSEZ2D January 2014 – October 2021 TCA9539-Q1
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | VCC | MIN | TYP (1) | MAX | UNIT | ||
|---|---|---|---|---|---|---|---|---|
| VIK | Input diode clamp voltage | II = –18 mA | 1.65 V to 3.6 V | –1.2 | V | |||
| VPORR | Power-on reset voltage, VCC rising | VI = VCC or GND | 1.65 V to 3.6 V | 1.2 | 1.5 | V | ||
| VPORF | Power-on reset voltage, VCC falling | VI = VCC or GND | 1.65 V to 3.6 V | 0.75 | 1 | V | ||
| VOH | P-port high-level output voltage (2) | IOH = –8 mA | 1.65 V | 1.2 | V | |||
| 2.3 V | 1.8 | |||||||
| 3 V | 2.6 | |||||||
| 3.6 V | 3.3 | |||||||
| IOH = –10 mA | 1.65 V | 1 | ||||||
| 2.3 V | 1.7 | |||||||
| 3 V | 2.5 | |||||||
| 3.6 V | 3.2 | |||||||
| IOL | SDA | VOL = 0.4 V | 1.65 V to 3.6 V | 3 | mA | |||
| P port (3) | VOL = 0.5 V | 8 | ||||||
| VOL = 0.7 V | 10 | |||||||
| INT | VOL = 0.4 V | 3 | ||||||
| II | SCL, SDA | VI = VCC or GND | 1.65 V to 3.6 V | ±1 | μA | |||
| A0, A1, RESET | ±1 | |||||||
| IIH | P port | VI = VCC | 1.65 V to 3.6 V | 1 | μA | |||
| IIL | P port | VI = GND | 1.65 V to 3.6 V | –1 | μA | |||
| ICC | Operating mode | VI = VCC or GND, IO = 0, I/O = inputs, fSCL = 400 kHz, no load | 3.6 V | 10 | 30 | μA | ||
| 2.7 V | 5 | 19 | ||||||
| 1.95 V | 4 | 11 | ||||||
| Standby mode | IO = 0, I/O = inputs, fSCL = 0 kHz, no load | VI = VCC | 3.6 V | 1.1 | 5 | |||
| 2.7 V | 1 | 4.5 | ||||||
| 1.95 V | 0.4 | 3.5 | ||||||
| VI = GND | 3.6 V | 1.1 | 13 | |||||
| 2.7 V | 1 | 9.5 | ||||||
| 1.95 V | 0.4 | 6.5 | ||||||
| Ci | SCL | VI = VCC or GND | 1.65 V to 3.6 V | 3 | 8 | pF | ||
| Cio | SDA | VIO = VCC or GND | 1.65 V to 3.6 V | 3 | 9.5 | pF | ||
| P port | 3.7 | 9.5 | ||||||