ZHCSO35A August 2020 – May 2021 SN74HCS165
PRODUCTION DATA
| PARAMETER | VCC | Operating free-air temperature (TA) | UNIT | |||||
|---|---|---|---|---|---|---|---|---|
| 25°C | –40°C to 125°C | |||||||
| MIN | MAX | MIN | MAX | |||||
| fclock | Clock frequency | 2 V | 49 | 43 | MHz | |||
| 4.5 V | 130 | 120 | ||||||
| 6 V | 170 | 150 | ||||||
| tw | Pulse duration |
SH/LD low |
2 V | 6 | 7 | ns | ||
| 4.5 V | 6 | 7 | ||||||
| 6 V | 6 | 7 | ||||||
|
CLK high or low |
2 V | 7 | 11 | |||||
| 4.5 V | 6 | 7 | ||||||
| 6 V | 6 | 7 | ||||||
|
tsu |
Setup time |
SH/LD high before CLK↑ | 2 V | 13 | 21 | ns | ||
| 4.5 V | 5 | 7 | ||||||
| 6 V | 4 | 6 | ||||||
|
SER before CLK↑ |
2 V | 8 | 14 | |||||
| 4.5 V | 4 | 6 | ||||||
| 6 V | 4 | 6 | ||||||
|
CLK INH low before CLK↑ |
2 V | 6 | 9 | |||||
| 4.5 V | 4 | 5 | ||||||
| 6 V | 4 | 5 | ||||||
|
CLK INH high before CLK↑ |
2 V | 6 | 9 | |||||
| 4.5 V | 4 | 5 | ||||||
| 6 V | 4 | 5 | ||||||
| Data before SH/LD↑ | 2 V | 9 | 17 | |||||
| 4.5 V | 4 | 6 | ||||||
| 6 V | 4 | 6 | ||||||
|
th |
Hold time |
Ser data after CLK↑ |
2 V | 0 | 0 | ns | ||
| 4.5 V | 0 | 0 | ||||||
| 6 V | 0 | 0 | ||||||
| PAR data after SH/LD↑ | 2 V | 5 | 6 | |||||
| 4.5 V | 4 | 5 | ||||||
| 6 V | 3 | 4 | ||||||
| SH/LD high after CLK↑ | 2 V | 0 | 0 | |||||
| 4.5 V | 0 | 0 | ||||||
| 6 V | 0 | 0 | ||||||