over operating free-air temperature range (unless otherwise noted)(1)
|
MIN |
MAX |
UNIT |
| VCC |
Supply voltage range |
–0.5 |
7 |
V |
| IIK |
Input clamp
current(2) |
VI < 0 or
VI > VCC |
|
±20 |
mA |
| IOK |
Output clamp current(2) |
VO < 0 or
VO > VCC |
|
±20 |
mA |
| IO |
Continuous output current |
VO = 0 to
VCC |
|
±25 |
mA |
|
Continuous current through VCC
or GND |
|
±50 |
mA |
| TJ |
Junction temperature |
|
150 |
°C |
| Tstg |
Storage temperature |
–65 |
150 |
°C |
(1) Stresses beyond those listed
under
absolute maximum ratings may cause permanent damage to the device.
These are stress ratings only and functional operation of the device at these or
any other conditions beyond those indicated under
Section 5.2 is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may
affect device reliability.
(2) The input and output voltage
ratings may be exceeded if the input and output current ratings are