over operating free-air temperature range (unless otherwise
noted)(1)
| MIN | MAX | UNIT |
|---|
| VCC | Supply voltage(2) | | 18 | V |
| VI | Input voltage | CONT, RESET, THRES, TRIG | | VCC | V |
| IO | Output current | | ±225 | mA |
| TJ | Operating virtual junction temperature | | 150 | °C |
| Case temperature for 60
seconds | FK package | | 260 | °C |
| Lead temperature 1.6mm (1/16
inch) from case | JG package, 60 seconds | | 300 | °C |
| Tstg |
Storage temperature |
–65 |
150 |
°C |
(1) Operation outside the Absolute Maximum
Ratings may cause permanent device damage. Absolute Maximum
Ratings do not imply functional operation of the device at these or any
other conditions beyond those listed under Recommended Operating
Conditions. If used outside the Recommended Operating Conditions
but within the Absolute Maximum Ratings, the device may not be fully
functional, and this may affect device reliability, functionality, performance,
and shorten the device lifetime.
(2) All voltage values are with respect to GND.