ZHCSU10P March 2000 – February 2025 LP2981-N
PRODUCTION DATA
Table 6-1 shows the conditions that lead to the different modes of operation. See the Electrical Characteristics table for parameter values.
| OPERATING MODE | PARAMETER | |||
|---|---|---|---|---|
| VIN | VON/OFF | IOUT | TJ | |
| Normal operation | VIN > VOUT(nom) + VDO and VIN > VIN(min) | VON/OFF > VON/OFF(HI) | IOUT < IOUT(max) | TJ < TSD(shutdown) |
| Dropout operation | VIN(min) < VIN < VOUT(nom) + VDO | VON/OFF > VON/OFF(HI) | IOUT < IOUT(max) | TJ < TSD(shutdown) |
| Disabled (any true condition disables the device) |
VIN < VUVLO | VON/OFF < VON/OFF(LOW) | Not applicable | TJ > TSD(shutdown) |