ZHCSL09C April 2020 – December 2020 LM7480-Q1
PRODUCTION DATA
| DESIGN PARAMETER | EXAMPLE VALUE |
|---|---|
| Operating Input Voltage Range | 24-V battery, 6 V during cold crank 200-V unsuppressed load lump |
| Output Voltage | 6 V during cold crank and 37.0 V during load dump |
| Output Power | 25 W |
| Output Current Range | 2-A Nominal, 2.5-A Peak |
| Input Capacitance | 0.1-μF minimum |
| Output Capacitance | 0.1-μF minimum, 220-μF typical hold-up capacitance |
| Overvoltage Cut-Off Threshold | 37.0 V |
| Overvoltage Clamp | Output clamped between 34.5 V and 37.5 V |
| Automotive Transient Immunity Compliance | ISO 7637-2 and ISO 16750-2 including 200-V unsuppressed load dump Pulse 5 A and –600-V 50-Ω ISO-7637 Pulse 1 |