ZHCSEJ7B October 2015 – April 2018 DRV2605L-Q1
PRODUCTION DATA.
The DRV2605L-Q1 has multiple modes for playing waveforms, as well as a calibration mode and a diagnostic mode. Table 2 lists the available modes.
| MODE | MODE[2:0] | N_PWM_ANALOG |
|---|---|---|
| Internal trigger mode | 0 | X |
| External Trigger mode (edge) | 1 | X |
| External trigger mode (level) | 2 | X |
| Analog input mode | 3 | 0 |
| PWM mode | 3 | 1 |
| Audio-to-vibe mode | 4 | X |
| RTP mode | 5 | X |
| Diagnostics mode | 6 | X |
| Calibration mode | 7 | X |