SLVK163 November 2023 TPS7H6003-SP
PRODUCTION DATA
HDR devices were stressed up to 100 krad(Si) for biased and unbiased conditions.
| Total Samples: 25 units + 1 control | ||||
|---|---|---|---|---|
| Exposure Levels: | ||||
| 3 krad(Si) | 10 krad(Si) | 30 krad(Si) | 50 krad(Si) | 100 krad(Si) |
| 134, 137, 138, 139, 236 | 237, 241, 242, 243, 244 | 132, 133, 135, 245, 246 | 172, 173, 174, 183, 186 | 178, 179, 180, 181, 182 |
| Total Samples: 25 units + 1 control | ||||
|---|---|---|---|---|
| Exposure Levels: | ||||
| 3 krad(Si) | 10 krad(Si) | 30 krad(Si) | 50 krad(Si) | 100 krad(Si) |
| 58, 59, 60, 61, 62 | 63, 64, 65, 66, 150 | 141, 144, 145, 146, 147 | 67, 68, 69, 71, 72 | 95, 102, 104, 105, 106 |