SFFSA42A December 2024 – May 2025 UCC33020 , UCC33020-Q1 , UCC33410 , UCC33410-Q1 , UCC33420 , UCC33420-Q1
This section provides functional safety failure in time (FIT) rates for the VSON-12 package of UCC33010, UCC33010-Q1, UCC33020, UCC33020-Q1, UCC33410, UCC33410-Q1, UCC33420, UCC33420-Q1 based on two different industry-wide used reliability standards:
| FIT IEC TR 62380 / ISO 26262 | Power Dissipation | FIT (Failures Per 109 Hours) |
|---|---|---|
| Total component FIT rate | 0.5W | 13 |
| 1W | 18 | |
| 1.23W | 20 | |
| Die FIT rate | 0.5W | 4 |
| 1W | 8 | |
| 1.23W | 10 | |
| Package FIT rate | 0.5W | 9 |
| 1W | 10 | |
| 1.23W | 10 |
The failure rate and mission profile information in Table 2-1 comes from the reliability data handbook IEC TR 62380 / ISO 26262 part 11:
| Table | Category | Reference FIT Rate | Reference Virtual TJ |
|---|---|---|---|
| 5 | CMOS,
BICMOS Digital, analog, or mixed | 60 FIT | 70°C |
The reference FIT rate and reference virtual TJ (junction temperature) in Table 2-2 come from the Siemens Norm SN 29500-2 tables 1 through 5. Failure rates under operating conditions are calculated from the reference failure rate and virtual junction temperature using conversion information in SN 29500-2 section 4.