ZHCSJN4C February 2018 – February 2020 TPS2HB16-Q1
PRODUCTION DATA.
| PIN | I/O | DESCRIPTION | ||
|---|---|---|---|---|
| NO. | Version A/B | Version F | ||
| GND | 1 | 1 | - | Device ground |
| SNS | 2 | 2 | O | Sense output |
| LATCH | 3 | 3 | I | Sets fault handling behavior (latched or auto-retry) |
| EN1 | 4 | 4 | I | Channel 1 control input, active high |
| ILIM1 | 5 | - | O | Connect pull-up resistor to VBB to set current-limit threshold on CH1 |
| FLT1 | - | 5 | O | Open drain fault indication |
| VOUT1 | 6-8 | 6-8 | O | Channel 1 output |
| VOUT2 | 9-11 | 9-11 | O | Channel 2 output |
| ILIM2 | 12 | - | O | Connect pull-up resistor to VBB to set current-limit threshold on CH2 |
| FLT2 | - | 12 | O | Open drain fault indication |
| EN2 | 13 | 13 | I | Channel 2 control input, active high |
| SEL1 | 14 | 14 | I | Diagnostics select 1. No functionality on version F; tie to device ground through 10 kΩ resistor |
| SEL2 | 15 | 15 | I | Diagnostics select 2 |
| DIA_EN | 16 | 16 | I | Diagnostic enable, active high |
| VBB | Exposed Pad | Exposed Pad | I | Power supply input |