ZHCSQ19A June 2023 – September 2024 TMUX582F-SEP
PRODUCTION DATA
請參考 PDF 數(shù)據(jù)表獲取器件具體的封裝圖。
| 參數(shù) | 測試條件 | TA | 最小值 | 典型值 | 最大值 | 單位 | |
|---|---|---|---|---|---|---|---|
| 模擬開關(guān) | |||||||
| RON | 導(dǎo)通電阻 | VS = 0V 至 7.8V,IS = -1mA | -55°C 至 +125°C | 180 | 400 | ? | |
| ΔRON | 通道間的導(dǎo)通電阻不匹配 | VS = 0V 至 7.8V,IS = -1mA | -55°C 至 +125°C | 5 | 13 | ? | |
| RFLAT | 導(dǎo)通電阻平坦度 | VS = 0V 至 7.8V,IS = -1mA | -55°C 至 +125°C | 7 | 80 | ? | |
| RON_DRIFT | 導(dǎo)通電阻漂移 | VS = 6V,IS = –1mA | -55°C 至 +125°C | 1.2 | ?/°C | ||
| IS(OFF) | 源極關(guān)斷漏電流 | 開關(guān)狀態(tài)為關(guān)斷,VS = 1V/10V,VD = 10V/1V,VDD = 13.2V | -55°C 至 +125°C | -4.5 | 4.5 | nA | |
| ID(OFF) | 漏極關(guān)斷漏電流 | 開關(guān)狀態(tài)為關(guān)斷,VS = 1V/10V,VD = 10V/1V,VDD = 13.2V | -55°C 至 +125°C | -15 | 15 | nA | |
| IS(ON),I,D(ON) | 通道導(dǎo)通漏電流 | 開關(guān)狀態(tài)為導(dǎo)通,VS = 懸空,VD = 1V/10V,VDD = 13.2V | -55°C 至 +125°C | -23 | 23 | nA | |
| 故障條件 | |||||||
| IS(FA) | 過壓期間的 輸入漏電流 |
VS = +60V,GND = 0V,VDD = VFP = 13.2V,VSS = VFN = 0V | 25°C | ±145 | μA | ||
| IS(FA) | 使用接地電源時 過壓期間的 輸入漏電流 |
VS = +60V,GND = 0V,VDD = VSS = VFP = VFN= 0V,VEN = VAx = 0V 或懸空 | 25°C | ±135 | μA | ||
| IS(FA) | 使用懸空電源時 過壓期間的 輸入漏電流 |
VS = +60V,GND = 0V,VDD = VSS = VFP = VFN= 懸空,VEN = VAx = 0V 或懸空 | 25°C | ±135 | μA | ||
| ID(FA) | 過壓期間的 輸出漏電流 |
VS = +60V,GND = 0V,VDD = VFP = 13.2V,VSS = VFN = 0V | -55°C 至 +125°C | -100 | 100 | nA | |
| ID(FA) | 使用接地電源時 過壓期間的 輸出漏電流 |
VS = +60V,GND = 0V,VDD = VSS = VFP = VFN= 0V,VEN = VAx = 0V 或懸空 | -55°C 至 +125°C | -550 | 550 | nA | |
| ID(FA) | 使用懸空電源時 過壓期間的 輸出漏電流 |
VS = +60V,GND = 0V,VDD = VSS = VFP = VFN= 懸空,VEN = VAx = 0V 或懸空 | 25°C | ±8 | μA | ||
| 數(shù)字輸入/輸出 | |||||||
| IIH | 高電平輸入電流 | VEN = VAx = VDD | -55°C 至 +125°C | -2.5 | 2.5 | μA | |
| IIL | 低電平輸入電流 | VEN = VAx = 0V | -55°C 至 +125°C | -1.5 | 1.5 | μA | |
| 開關(guān)特性 | |||||||
| tON (EN) | 啟用開通時間 | VS = 8V, RL = 4kΩ,CL= 12pF |
25°C | 160 | ns | ||
| tOFF (EN) | 啟用關(guān)閉時間 | VS = 8V, RL = 4kΩ,CL= 12pF |
25°C | 420 | ns | ||
| tTRAN | 轉(zhuǎn)換時間 | VS = 8V, RL = 4kΩ,CL= 12pF |
25°C | 160 | ns | ||
| tBBM | 先斷后合延時時間 | VS = 8V, RL = 4kΩ,CL= 12pF |
25°C | 90 | ns | ||
| tRESPONSE | 故障響應(yīng)時間 | VFP = 8V,VFN = 0V, RL = 4kΩ,CL= 12pF |
25°C | 225 | ns | ||
| tRECOVERY | 故障恢復(fù)時間 | VFP = 8V,VFN = 0V, RL = 4kΩ,CL= 12pF |
25°C | 0.75 | μs | ||
| tRESPONSE(FLAG) | 故障標(biāo)志響應(yīng)時間 | VFP = 8V,VFN = 0V,VPU = 5V, RPU = 1kΩ,CL= 12pF |
25°C | 120 | ns | ||
| tRECOVERY(FLAG) | 故障標(biāo)志恢復(fù)時間 | VFP = 8V,VFN = 0V,VPU = 5V, RPU = 1kΩ,CL= 12pF |
25°C | 0.75 | μs | ||
| QINJ | 電荷注入 | VS = 6V,CL = 1nF,RS = 0Ω | 25°C | -11 | pC | ||
| OISO | 關(guān)斷隔離 | RS = 50Ω,RL = 50Ω,CL = 5pF, VS = 200mVRMS,VBIAS = 2V,f = 1MHz |
25°C | -75 | dB | ||
| XTALK | 通道間串?dāng)_ | RS = 50Ω,RL = 50Ω,CL = 5pF, VS = 200mVRMS,VBIAS = 2V,f = 1MHz |
25°C | -90 | dB | ||
| BW | -3dB 帶寬 | RS = 50Ω,RL = 50Ω,CL = 5pF, VS = 200mVRMS,VBIAS = 2V,f = 1MHz |
25°C | 130 | MHz | ||
| ILOSS | 插入損耗 | RS = 50Ω,RL = 50Ω,CL = 5pF, VS = 200mVRMS,VBIAS = 2V,f = 1MHz |
25°C | -9 | dB | ||
| THD+N | 總諧波失真 + 噪聲 | RS = 40Ω,RL = 10kΩ,VS = 6VPP,VBIAS = 6V,f = 20Hz 至 20kHz | 25°C | 0.0025 | % | ||
| CS(OFF) | 輸入關(guān)斷電容 | f = 1MHz,VS = 6V | 25°C | 4 | pF | ||
| CD(OFF) | 輸出關(guān)斷電容 | f = 1MHz,VS = 6V | 25°C | 31 | pF | ||
| CS(ON),CD(ON) | 輸入/輸出導(dǎo)通電容 | f = 1MHz,VS = 6V | 25°C | 34 | pF | ||
| 電源 | |||||||
| IDD | VDD 電源電流 | VDD = VFP = 13.2V,VSS = VFN = 0V,VEN/VAx = 0V、5V 或 VDD,VS = 6V | -55°C 至 +125°C | 0.6 | mA | ||
| ISS | VSS 電源電流 | VDD = VFP = 13.2V,VSS = VFN = 0V,VEN/VAx = 0V、5V 或 VDD,VS = 6V | -55°C 至 +125°C | 0.5 | mA | ||
| IGND | GND 電流 | VDD = VFP = 13.2V,VSS = VFN = 0V,VEN/VAx = 0V、5V 或 VDD,VS = 6V | 25°C | 0.075 | mA | ||
| IFP | VFP 電源電流 | VDD = VFP = 13.2V,VSS = VFN = 0V,VEN/VAx = 0V、5V 或 VDD,VS = 6V | 25°C | 10 | μA | ||
| IFN | VFN 電源電流 | VDD = VFP = 13.2V,VSS = VFN = 0V,VEN/VAx = 0V、5V 或 VDD,VS = 6V | 25°C | 10 | μA | ||
| IDD(FA) | 故障條件下的 VDD 電源電流 | VS = +60V,VDD = VFP = 13.2V,VSS = VFN = 0V,VEN/VAx = 0V、5V 或 VDD | -55°C 至 +125°C | 1.25 | mA | ||
| ISS(FA) | 故障條件下的 VSS 電源電流 | VS = +60V,VDD = VFP = 13.2V,VSS = VFN = 0V,VEN/VAx = 0V、5V 或 VDD | -55°C 至 +125°C | 0.75 | mA | ||
| IGND(FA) | 故障條件下的 GND 電流 | VS = +60V,VDD = VFP = 13.2V,VSS = VFN = 0V,VEN/VAx = 0V、5V 或 VDD | -55°C 至 +125°C | 0.2 | mA | ||
| IFP(FA) | 故障條件下的 VFP 電源電流 | VS = +60V,VDD = VFP = 13.2V,VSS = VFN = 0V,VEN/VAx = 0V、5V 或 VDD | 25°C | 20 | μA | ||
| IFN(FA) | 故障條件下的 VFN 電源電流 | VS = +60V,VDD = VFP = 13.2V,VSS = VFN = 0V,VEN/VAx = 0V、5V 或 VDD | 25°C | 20 | μA | ||
| IDD(DISABLE) | VDD 電源電流(禁用模式) | VDD = VFP = 13.2V,VSS = VFN = 0V,VAx = 0V、5V 或 VDD,VEN = 0V,VS = 0V | -55°C 至 +125°C | 0.6 | mA | ||
| ISS(DISABLE) | VSS 電源電流(禁用模式) | VDD = VFP = 13.2V,VSS = VFN = 0V,VAx = 0V、5V 或 VDD,VEN = 0V,VS = 0V | -55°C 至 +125°C | 0.5 | mA | ||