Table 8-1 lists the functional modes of the SN74LV393B-EP.
Table 8-1 Operating Mode Table| INPUTS | FUNCTION(1) |
|---|
| CLK | CLR |
|---|
| ↑ | L | No change |
| ↓ | L | Advance to next stage |
| X | H | All outputs L |
(1) H = High Voltage Level, L = Low Voltage Level, X = Do Not Care, ↑ = Low to High transition