| PARAMETER | TEST CONDITIONS | VCC | MIN | TYP | MAX | UNIT | ||
|---|---|---|---|---|---|---|---|---|
| VOH | IOH = –50 μA | TA = 25°C | 2 V | 1.9 | 2 | V | ||
| TA = –40°C to 85°C | 1.9 | |||||||
| TA = –40°C to 125°C Recommended | 1.9 | |||||||
| IOH = –50 μA | TA = 25°C | 3 V | 2.9 | 3 | ||||
| TA = –40°C to 85°C | 2.9 | |||||||
| TA = –40°C to 125°C Recommended | 2.9 | |||||||
| IOH = –50 μA | TA = 25°C | 4.5 V | 4.4 | 4.5 | ||||
| TA = –40°C to 85°C | 4.4 | |||||||
| TA = –40°C to 125°C Recommended | 4.4 | |||||||
| IOH = –4 mA | TA = 25°C | 3 V | 2.58 | |||||
| TA = –40°C to 85°C | 2.48 | |||||||
| TA = –40°C to 125°C Recommended | 2.48 | |||||||
| IOH = –8 mA | TA = 25°C | 4.5 V | 3.94 | |||||
| TA = –40°C to 85°C | 3.8 | |||||||
| TA = –40°C to 125°C Recommended | 3.8 | |||||||
| VOL | IOL = 50 μA | TA = 25°C | 2 V | 0.1 | V | |||
| TA = –40°C to 85°C | 0.1 | |||||||
| TA = –40°C to 125°C Recommended | 0.1 | |||||||
| IOL = 50 μA | TA = 25°C | 3 V | 0.1 | |||||
| TA = –40°C to 85°C | 0.1 | |||||||
| TA = –40°C to 125°C Recommended | 0.1 | |||||||
| IOL = 50 μA | TA = 25°C | 4.5 V | 0.1 | |||||
| TA = –40°C to 85°C | 0.1 | |||||||
| TA = –40°C to 125°C Recommended | 0.1 | |||||||
| IOL = 4 mA | TA = 25°C | 3 V | 0.36 | |||||
| TA = –40°C to 85°C | 0.44 | |||||||
| TA = –40°C to 125°C Recommended | 0.44 | |||||||
| IOL = 8 mA | TA = 25°C | 4.5 V | 0.36 | |||||
| TA = –40°C to 85°C | 0.44 | |||||||
| TA = –40°C to 125°C Recommended | 0.44 | |||||||
| II | VI = 5.5 V or GND | TA = 25°C | 0 V to 5.5 V | ±0.1 | μA | |||
| TA = –40°C to 85°C | ±1 | |||||||
| TA = –40°C to 125°C Recommended | ±1 | |||||||
| IOZ | VI = VCC or GND, VO = VCC or GND, OE = VIH or VIL, | QA – QH | TA = 25°C | 5.5 V | ±0.25 | μA | ||
| TA = –40°C to 85°C | ±2.5 | |||||||
| TA = –40°C to 125°C Recommended | ±2.5 | |||||||
| ICC | VI = VCC or GND, | IO = 0 | TA = 25°C | 5.5 V | 4 | μA | ||
| TA = –40°C to 85°C | 40 | |||||||
| TA = –40°C to 125°C Recommended | 40 | |||||||
| Ci | VI = VCC or GND | TA = 25°C | 5 V | 3 | 10 | pF | ||
| TA = –40°C TO 85°C | 10 | |||||||
| CO | VO = VCC or GND, | TA = 25°C | 5 V | 5.5 | pF | |||