over operating free-air temperature range (unless
otherwise noted)(1)
|
MIN |
MAX |
UNIT |
| VCC |
Supply-voltage |
-0.5 |
6 |
V |
| IIK |
Input diode current |
(VI < -0.5 V or VI > VCC
+ 0.5 V) |
|
±20 |
mA |
| IOK |
Output diode current |
(VO < -0.5 V or VO > VCC
+ 0.5 V) |
|
±50 |
mA |
| IO |
Output source or sink current per output pin |
(VO > -0.5 V or VO < VCC
+ 0.5 V) |
|
±50 |
mA |
|
VCC or ground current, ICC or
IGND |
|
±100 |
mA(2) |
| Tstg |
Storage temperature |
-65 |
+150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum
Ratings may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond
those indicated under Recommended Operating Conditions is not implied. Exposure
to absolute-maximum-rated conditions for extended periods may affect device
reliability.
(2) For up to 4 outputs per device;