Table 9-2 shows the design parameters for this application example.
| PARAMETER | VALUE |
|---|---|
| Typical input voltage, VIN | 12 V |
| Undervoltage lockout set point, VINUVLO | 6.5 V |
| OV set point, VINOVP | 36 V |
| Maximum load current, IOUT | 20 A |
| Overcurrent protection threshold, IOC | 24 A |
| Short-circuit protection threshold, ISC | 30 A |
| Fault timer period (tOC) | 1 ms |
| Fault response | Auto-retry |
Input reverse polarity protection | Yes |